- Class 1.0 Accuracy
- Compliance with IS 16444
- Four Quadrant measurements.
- Three Phase 4Wire 60A/90/120A Load switch.
- Active and Apparent measurements.
- Both in import and export.
- 0.000001kWh Resolution measurement.
- Load survey and Day survey as per standards.
- Neutral and Phase measurements.
- Programmable Block Window and Sliding
Window MD Calculation methods.
- Programmable MD integration period and Reset dates.
- Active, apparent, Import and Export MD registers.
|
ELECTRICAL
Voltage and Power Supply
|
- Voltage - 3 x 240V AC
- Frequency 50Hz (Standard).
- Range: 47.5Hz -52.5Hz
- Power supply surge - 440V
- Burden< 10VA/Phase (as per IS 16444)
- Power consumption ≤ 5 Watt(As per Standard)
|
Current |
- Current ranges 10-60A/10-100A/5-10A
- Over current: 30 times l max for 0.5 cycles
- Burden < 0.5VA/Phase
- Operating Temperature 27°C
- UC1 Load switch ranges 120A
|
Measured Energy Values |
- Three element four quadrant
- Import/Export/Net Wh , Varh and VAh
- Per quadrant Wh ,Varh and VAh
- Absolute Wh , Varh and VAh
- Phase A,B,C and Total
|
Security |
- Multi-level security (user name and password
including encrypted log-in)
- Up to six individual users
- AES128 bit encryption
|
Meter Variants |
- 3 Phase 4W 5-30A
- 3 Phase 4W 10-60A
- 3 Phase 4W 10-100A
|
Time of Use |
- Programmable TOD
- 8 TOD Timings
|
Parameter Selection on communication |
- User Selectable, Can select different parameters for
Different sources.
|
LCD Display |
- LCD seven segment display
- Real-time Programmable display parameters
- Auto Push and INFO Mode
- Feature icons for special conditions
- Communication indication
- Display digit size: 10mm (H)*5mm
- Definable enunciators
- Display available even without mains power
|
Environmental |
- Operating temperature range: -25'C to 60'C
- Limit range: -40'C to 70'C
- Storage range: -40'C to 80'C
- Relative humidity: Up to 75% mean, 95% non
- condensing for 30 days
- Ingress protection: IP51
- Sealing: break-open sealing provision as per Standards
- Material: Engineering plastic/PC/Brass terminals
|
Load/day survey/Profile |
- AMI Ready - Instant push and pull
- Inbuilt storage as per standard - expandable at factory
- Intervals programmable from 1 to 60 minutes
- Two independent surveys
- Energy, Instantaneous readings ,Pulsing inputs as channel sources
- Ability to store average/minimum/maximum values for interval duration
|
Physical Dimension |
- Weight - 2.5 Kilograms
- Dimensions LOH - 292.5 mm(L) x 175mm(D) x95mm(H)
|
Time Clock and Calendar |
- Inbuilt RTC
- Accuracy (internal) as per standard, within 15 seconds per month
- Backup time of 10 years without power (lithium battery)
- Supports Daylight Saving Time
|
Communication Variants |
- RS485 Serial port communication.
- LoRa
- NBIoT
- GPRS
- Ethernet Interface.
|
System Integration Support |
- Interoperable DLMS compliance (Optional).
- Self-Integrable with IS 16444 compliant MDMS.
- Self-Integrable with multi-vendor Cams.
- Programmable Alarms and instant push.
|
Battery Options |
- Internal battery for display and backup.
- Separate Battery for RTC
|
Tamper Detection and Alarms |
- Provision for sealing with conventional wire or plastic seals.
- Bypassing current and reverse current.
- Advanced tamper detection and logging.
- Pre-programmed alarms for meter self-check.
- Alarms trigger, enunciators, relay outputs or communications event
- Alarm Trigger Push - First breath. last GASP and instant alarm push
- Alarms are stored in event logs
- Self-diagnostic feature Up to 200
Events storage.
|
Prepayment |
- Inbuilt Prepayment mode.
- Real-time prepayment and post payment selection.
- Remote Recharge capable.
- Configuration of Mode over OTA.
- Energy (kWh) and Value (Currency) based prepayment.
- Programmable tariff plan.
|
Net Metering |
- Inbuilt Net metering Mode (Optional).
- Real-time Net metering Swap (Optional).
- Configuration OTA remotely (Optional).
- Import, Export and Net Energy measurement (Optional).
|
Data Availability |
- From 1min to 60min interval (Programmable)
- Daily data for 30 days.
- Monthly data for 12 months.
|